Table 4

Cost estimation of the set-ups and their monetary benefits.

Cost ($) Static FPC Tracked FPC Concentrated FPC
Collector cost 756 756 756
Pump cost 50 50 50
Tracking cost 0 36 36
Concentrator cost 0 0 125
Pumping energy cost 108 108 108
Tracking energy cost 0 36 0
Total cost ($) 914 950 1039
  Thermal energy (kWh/day) Equivalent electrical energy (kWh/day) Yearly electrical energy (MWh/year) Yearly saving ($)
Static 39.2 11.76 3.5 304
Single axis tracking (vertical) 41.7 12.51 3.7 322
Single axis tracking (horizontal) 43.6 13.08 3.9 340
Double axis tracking 45.1 13.51 4.1 357
Concentrator 56.2 16.86 5.1 444