Table 5

Reference case and variation of input data in the parametric study based on the principle one-factor-at-a-time and including 29 cases in total.

Parameter Reference case Case Variation

1 2 3
Orientation South A West North East
Window wall ratio (S/W/N/E) 0.26/0/0.18/0 B 0.13/0/0.18/0 0.52/0/0.18/0 0.78/0/0.18/0
Glazing Modern double
U = 1.2 W/(m2K)
g = 0.65
C Single
U = 5.7 W/(m2K)
g = 0.82
Old double
U = 3.0 W/(m2K)
g = 0.77
Modern triple
U = 0.7 W/(m2K)
g = 0.5
Shading device τ = 0.1 Da τ = 0.2 τ = 0.3 τ = 0.4
θc = 25 °C Db θc = 23 °C θc = 27 °C θc = 29 °C
Variable Dc Fixed overhang (south façade only)
      w = 1 m w = 2 m  
Thermal insulation 0.06 m E 0.0 m 0.03 m 0.09 m
Nighttime ventilation 4 ACH Fa 0 ACH 2 ACH 6 ACH
10 p.m. to 7 a.m. Fb 6 p.m. to 7 a.m. 8 p.m. to 7 a.m. 12 p.m. to 7 a.m.
Thermal mass Massive internal walls G Lightweight internal walls All walls lightweight  